Many customers have reported that the new needle valve seals still fail quickly, leaking or getting damaged not long after replacement.
There are two core reasons behind this issue. First, the material of the seal is critical. Inferior materials tend to age and deform easily. We use imported seals that are far more wear-resistant and corrosion-resistant than standard alternatives, offering much longer service life. Second, shaft wear is the hidden culprit. Dry glue residue on the shaft will scratch its surface. When the shaft moves back and forth, even high-quality new seals will get damaged by these scratches.
Key reminder! Always check the shaft condition when replacing the seal. If wear is detected, repair or replace the shaft in a timely manner.
We are producing IGU lines, Insulating Glass Machine, Insulating Glass Argon Gas Filling Line, Insulating Glass Sealing Robot Line and all kinds of Special-Shaped Glass Sealing Robot, Insulated Glass household appliances with wire sealing machine.We have our own technology to supply you Customizable IGU machines and lines.
If you want to know more about our insulating glass machine line, welcome to subscribe to our YouTube channel.
上一篇:ALB GLASS Upgraded Base: No Brush Sinking Even Bearing Fails
下一篇:Insulating Glass Sealing Robot Line Speed Stuck? 1-2mm Gap Adjustment Method