Many friends have been asking a question: when the sealant applicator works at 0 degrees, it’s very stable, but when it operates at 90 degrees, wavy patterns appear. This issue is especially severe with sealant applicators that have been used for a long time.
The reason mainly lies in the V-shaped plates: first, the V-shaped plates wear out after long-term use; second, the flatness of the two V-shaped belts needs calibration after extended use. When the lower V-shaped belt is uneven, more wavy patterns will gradually appear on the upper part when the sealant applicator works at 90 degrees.
So, when such wavy patterns occur, everyone should pay attention to the flatness of the V-shaped belts and check and calibrate them in a timely manner.
We are producing IGU lines, Insulating Glass Machine, Insulating Glass Argon Gas Filling Line, Insulating Glass Sealing Robot Line and all kinds of Special-Shaped Glass Sealing Robot, Insulated Glass household appliances with wire sealing machine.We have our own technology to supply you Customizable IGU machines and lines.
If you want to know more about our insulating glass machine line, welcome to subscribe to our YouTube channel.
上一篇:Why Is White Sealant Output Low in Double Glass Sealing Robot Machines?
下一篇:Two Key Details for Choosing an Insulating Glass Sealing Machine